4.6 Extension 5: Stability Constraints
Accompanying Workbook: olm_extension_5.xlsx
The optimiser has additional configuration parameters to enforce additional stability constraints.
-
Bookend Minimum Fill Percentage:
This specifies the percentage of the safe fill level of a bookend compartment that is the minimum to which the compartment must be filled to satisfy the stability constraints.
By default the optimiser uses a value of 100%.
-
Large Compartment Ullage Restrictions:
The optimiser optionally enforces a constraint to restrict the amount of ullage in large compartments when the vehicle is loaded with certain products. The requirements of this constraint are taken from section 10.3.1.2 of the “Australian Code for the Transport of Dangerous Goods by Road & Rail”. 1
This constraint is enabled by default.
For a more detailed description of theses constraints please refer to the “Opturion Load Manager – Data Formats and Web Service” document.
Opturion Fuel wish to reduce the bookend minimum fill percentage to 85% and to disable the large compartment ullage restrictions.
The planner adds the Configuration sheet to include the additional information, as seen in Table 8.
| Parameter | Value |
| Bookend Minimum Fill Percentage | 90% |
| Disable Large Compartment Ullage Restrictions | TRUE |
Running the optimiser with this scenario produces the compartment volumes seen in Figure 24.